Essai Norme Catégorie

C411N Profometer corrosion

( Concrete )

  • ASTM C876
  • DGZFP B3
  • SIA 2006
  • JSCE E 601
  • JGJ/T 152
  • UNI 10174
  • RILEM TC 154-EMC

Thanks to the half-cell method, this device allows to analyse and evaluate the corrosion status and the corrosion potential of the reinforcement bars into the concrete. The equipment includes a touchscreen display 7’’, battery charger, cable on reel (25 m), USB cable, software, electrode and carrying case.

Also suitable to determine the location of the bars.
Measuring range: -999 to +999 mV
Precision: ± 1 mV
Dimensions: 250x162x62 mm
Weight: 2 kg approx

Request information

Memory: internal 8 GB flash memory

Regional settings: metric and imperial units and multi-language and timezone supported

Power input: 12 V ± 25 % / 1.5 A Battery: 3.6 V, 14 Ah

Battery lifetime: > 8h (in standard operating mode)

Humidity: < 95 % RH, non condensing

Operating temperature: -10 °C to +50 °C

IP classification: touchscreen IP54, universal probe IP67

Voltage measuring range: -1000 to + 1000 mV

Voltage resolution: 1 mV

Impedance: 100 MΩ

Sampling rate: 900 Hz